mab2008 (Electrical) 15 Feb 08 2:33
We are operating a Used Oil Lube refinery which generates water with very high CoD and TOC. We are using bioreactor process to treat the water but still the treated water gets high COD / BOD and cannot be discharged to local regulatory discharge network. Any suggestions to tackle this problem. Wehre to find expertise to refer the problem to. Appreciating responses on this thread

dbaird (Electrical) 15 Feb 08 6:16
If in USA contact:
http://www.crownsolutions.com/ David Baird

Sr Controls Designer
EET degree.
Journeyman Electrician.

bimr (Civil/Environme) 15 Feb 08 11:10
If your facility was properly designed, constructed, and operated, you would have no problems meeting the discharge requirements. There are similar wastewater treatment plants that accomplish this as standard practice.

字串9



Your question is too general to answer. Why don't you provide some specifics such as the types of unit processes involved and volume of flow?

A refinery wastewater treatment plant would typically include oil removal processes such as DAF, as well as an activated sludge process to remove dissolved organics.




mab2008 (Electrical) 21 Feb 08 7:14
Thanks for your response - both dbaird and bimr. You are correct that the design was not proper in the beginning and we are struggling till date. I will share this thread with my process engineers and would respond with more details.

In the meantime, please advise if you know of any contact in Middle East. We are running our plant in Saudi Arabia

bimr (Civil/Environme) 21 Feb 08 22:35
I would think that Fluor Daniel would be of assistance to you in the Middle East.

字串7




(Click:

Previous:NH3 in pure water systems   Next:water quality vs treatment methods
[Add TO Favorites] [TOP] [PRINT] [CLOCE WINDOWS]  
  Hot Article
·Turning radius for Truck & RV
·DESIGN OF GRILLAGE FOUNDATION
·Shrink/swell factors for earth
·Converting mm Hg to psia
·How to read a pump curve corre
·IDF curves HELP
·I-beam torsional stress calcul
·Fire Truck Turning template
·School Bus Parking Lot Design
·What is E80 Loading?
·Aquamine PVC Pipe - Thrust Blo
·Structural design of water tan
  Related Articles
·PE April 2008
·Reverse Curves
·Choosing between environmental
·TL rating for Strong-Post W-Be
·Score Lines in S.O.G.
·SEPA and HPA Requirements
·concrete pipe encasement
·hydraulic design of stilllling
·seeking advice
·Working From Home
·Design & analysis of Frame
·AutoTurn Roll-off and front lo
Power by DedeCms